Hangzhou Sino-cold Sci-tech Co., Ltd. is one of the most reliable manufacturers and suppliers of industrial water chiller in China. With abundant experience, we are committed to providing high quality custom service for global clients. Welcome to wholesale premium industrial water chiller at competitive price from our factory.
Working Principle
The refrigeration cycle is the same - compressor → condenser → expansion valve → evaporator - with the core difference being the "water loop" on the condensing side:
- The compressor discharges high-temperature, high-pressure refrigerant gas into the water-cooled condenser (mostly shell-and-tube)
- The refrigerant transfers heat to the cooling water outside the tubes and condenses into high-pressure liquid
- The warmed cooling water (about 30–37°C) is sent by the cooling pump to the cooling tower
- In the tower, hot water is sprayed and contacts air to evaporate, rejecting heat to the atmosphere; the water cools to about 32°C and is reused
- The refrigerant liquid is depressurized by the expansion valve, absorbing heat from the chilled water in the evaporator and producing cold water (typically 7°C)
- The chilled-water pump delivers the cold water to the load, completing the cooling cycle
In one sentence: heat goes refrigerant → cooling water → cooling tower → air, requiring two water loops (chilled-water side + cooling-water side).
Typical Structure (one extra water loop vs air-cooled)

|
Component |
Function |
|
Compressor (mainly screw / centrifugal) |
Provides refrigeration cycle power; suited to medium-large capacity |
|
Water-cooled condenser (shell-and-tube) |
Refrigerant – cooling water heat exchange |
|
Cooling tower |
Cooling-water evaporative heat rejection and reuse |
|
Cooling pump |
Drives cooling-water circulation |
|
Expansion valve |
Throttles and depressurizes |
|
Evaporator (shell-and-tube / flooded) |
Chilled-water heat exchange |
|
Chilled-water pump |
Delivers cold water to the load |
|
Electric control box (PLC / HMI) |
Temperature control, interlock, group control |
Advantages vs Disadvantages
Advantages
- High efficiency (high COP): low and stable condensing temperature; saves 10–30% power vs same-capacity air-cooled; clear electricity-cost advantage over long runs
- Unaffected by high ambient: heat rejection via cooling tower; cooling capacity barely derates in hot summer
- Low noise: no large exhaust fans; the host is quieter; good for indoor / plant use
- Suited to medium / extra-large capacity: screw and centrifugal units reach hundreds of kW to several MW; the mainstay for central AC and industry
- Long life, stable operation: stable conditions, small compressor load fluctuation


Suitable Applications
- Medium-large continuous operation: central AC, data centers, electronics plants, chemical, pharmaceutical
- Injection molding, extrusion, die-casting lines needing stable low-temperature chilled water
- Food freezing, beer fermentation, pharma purification process cooling
- Plants / buildings sensitive to electricity cost, with long run hours and a preference for low noise


Selection Tips
Capacity match + margin: size for the maximum heat load; for continuous operation leave a 10–20% margin
Cooling-tower capacity: design for the local wet-bulb temperature; enlarge in hot-humid regions
Water quality & treatment: in hard-water areas, use softened water / dosing / electronic descaling to prevent condenser scaling (1 mm scale cuts efficiency 10%+)
Cooling-water temperature: inlet typically 30/32°C, outlet 35/37°C; below this, confirm the compressor allowable range
Freeze protection: in northern winters, drain when stopped or add antifreeze, or choose a closed-circuit cooling tower
Efficiency certification: watch COP / IPLV; prefer variable-frequency compressor + VFD pump energy-saving configuration
Refrigerant & eco: new units mostly use low-GWP refrigerants such as R134a / R513A
Common Selection Comparison (supplement)
|
Dimension |
Air-Cooled Chiller |
Water-Cooled Chiller Unit |
|
Heat-rejection medium |
Air (fan) |
Cooling water + cooling tower |
|
Energy efficiency COP |
Lower |
Higher (saves 10–30% power) |
|
Initial investment |
Low |
Higher |
|
Installation |
Simple |
Complex (two loops + tower) |
|
Maintenance |
Low |
Higher (water treatment / cleaning) |
|
Environmental dependency |
Strong (averse to high heat) |
Weak |
|
Noise |
Higher |
Lower |
|
Suitable power |
Small-to-medium |
Medium-large / extra-large |